What is a Non Permit-Required Confined Space Checklist?

A non permit-required confined space checklist is a document used to assess and confirm that a confined space is safe to enter without the need for a permit or an attendant. The primary goal is to make sure that confined spaced does not contain hazards that can cause serious harm or death. The use of this form aims to mitigate risks and ensure the safety of workers in confined spaces.

What is a Non Permit-Required Confined Space?

According to the US Occupational Safety and Health Administration (OSHA), a non-permit confined space is any confined space that is not likely to cause harm to workers through atmospheric, mechanical, fire, or gaseous hazards. It is a place where hazards are “eliminated” enough to cause little to no risk to humans.

However, it’s important to note that even in non permit-required confined spaces, potential dangers might still exist due to factors such as:

  • limited entry and exit points;

  • confined movement; and

  • the presence or condition of certain work-related machinery.

Employers are still responsible for ensuring that workers receive proper training, are equipped with necessary safety protection, and follow established safety protocols. Regular assessments of the space’s conditions should also be conducted to verify that no unexpected hazards have emerged.

Importance of Using a Checklist for Confined Space Safety

It is important to keep non permit-required confined spaces free from hazards at all times, as changes in the amount and kinds of hazards will require employers to reevaluate that space. A non permit-required confined space checklist is essential in keeping said space in a safe working condition.

With the right checklist, you can ensure all non permit-required confined spaces are free of hazardous and harmful substances and practices. It can also help you document any possible risks that may happen or be spotted.

Additionally, by standardizing procedures through the checklist, there is consistency in the safety measures taken across different non permit-required confined spaces. In the process, it also helps in training and educating employees on the proper procedures and precautions to take when entering confined spaces, ensuring that there is no ambiguity in safety expectations. As a result, the risk of accidents is significantly reduced.

Furthermore, the checklist promotes and improves both compliance and accountability. Responsible individuals can verify that each step has been completed before granting entry, minimizing the chances of errors that could lead to accidents or injuries. At the same time, this ensures compliance with safety guidelines set by the employer, the area’s safety professionals, and international standards.

What to Include in a Non Permit-Required Confined Space Checklist

To ensure your non permit-required confined space is safe for use and work, create a checklist that includes fields for the following:

  • Evaluating if any new hazards will be introduced to the confined space from:

    • Work tasks

    • Chemicals

    • Equipment

    • Air monitors

  • Ensuring gasses such as the following are at safe working levels

    • Oxygen

    • Hydrogen sulfide

    • Carbon monoxide

    • Lower Explosive Limit (LEL) or Lower Flammable Limit (LFL)

  • Making sure the following are not present or are controlled so as to not cause harm or create other hazards:

    • Materials that can engulf different items

    • Exposed or unmaintained equipment

    • Stray electrical equipment

    • Unmanaged fall hazards

    • Asbestos or asbestos-generating materials

Non Permit-Required Confined Space Form

Prior to entering a non-permit required confined space, the space must be evaluated to performed in the space. The following checklist assists in this evaluation.

Evaluate if new hazards will be created by the planned work

No activities will be conducted that could create a hazard inside the confined space

Yes

No

N/A

No chemicals will be brought into the space that could create a hazard (such as solvents, toxic gasses, or adhesives)

Yes

No

N/A

No conditions exist around this space that could adversely affect anyone within the work area or those outside or near it

Yes

No

N/A

Air monitor has been calibrated within the last 12 months and is checked regularly

Yes

No

N/A

Verify that no atmospheric hazards exist and ensure these gasses are at safe working levels:

Oxygen

Yes

No

N/A

Hydrogen sulfide

Yes

No

N/A

Carbon monoxide

Yes

No

N/A

Lower Explosive Limit (LEL) or Lower Flammable Limit (LFL)

Yes

No

N/A

The space does not contain:

Materials that could engulf an entrant (such as water)

Yes

No

N/A

Exposed, unprotected, or unmaintained mechanical equipment

Yes

No

N/A

Exposed, unprotected, or stray electrical conductors

Yes

No

N/A

Unmanaged fall hazards

Yes

No

N/A

Asbestos or asbestos-generating materials

Yes

No

N/A

Sample PDF Report

Here is a sample non permit-required confined space checklist in a PDF format:

Non Permit-Required Confined Space Checklist Sample Report

Non Permit-Required Confined Space Checklist Sample PDF Report | SafetyCulture

This is a CTA image

Still looking for a checklist?

Create a custom checklist template instantly with AI

FAQs about Non Permit-Required Confined Space Checklists

RM

Article by

Roselin Manawis

SafetyCulture Content Specialist

View author profile

Related resources you might like

Powered by

Confined Space Supervisory Responsibilities Checklist

This checklist can be used as a guide to make sure that important safety measures are strictly implemented. Track improvement, compliance, and safety changes all in one place, and view results in one dashboard after.

Powered by

OSHA Confined Space Entry Procedure Checklist

This is a standard OSHA confined space safety checklist for checking if safety regulations are followed by workers before, during, and after work. Use this checklist to capture significant data while inspecting the area, equipment, and people involved. Share your audits with your supervisors and safety managers while on site.

Powered by

Confined Space Pre-Entry Inspection

This pre-entry inspection form can be used for both permit-required and non-permit required confined spaces. With this, you can evaluate if the rules in place are enough for certain risks and hazards, ensure if workers are competent and trained to perform the job, and if the proper equipment is used and worn properly.

Articles

Vendor Risk Management Software

Discover the 10 best vendor risk management software and efficiently manage potential threats associated with vendors with your top pick.

Lone Working in Healthcare: The Ultimate Guide

Learn more about lone working in healthcare, its importance and regulations on how to keep lone workers safe.

Inspection Checklists

Access free inspection checklists and templates to simplify site inspections, improve safety, and complete tasks efficiently.